PRODUCTS · SPECIAL-APPLICATION CAPACITORS

Six capacitor families. Engineered around the application.

Marxelec manufactures special-application capacitors for electrical duties where the operating conditions matter as much as the rating. The range covers energy-storage and discharge capacitors, high-voltage DC and DC filter capacitors, surge protection capacitors, water-cooled and air-cooled capacitors, PD-free voltage dividers and import-substitute capacitor development.

Every capacitor is tested against its applicable IEC or equivalent IS inspection and test plan before despatch.

6 SPECIAL-APPLICATION FAMILIES
4 decades FOUNDER ENGINEERING DISCIPLINE
20+ EXPORT COUNTRIES
150+ CLIENTS SERVED

Our Capability

Capability indicators apply to relevant product families. Final ratings are confirmed after application review.

VOLTAGE CAPABILITY Up to 160 kV DC
PEAK DISCHARGE CURRENT >500 kA
REACTIVE OUTPUT Up to 7200 kVAr
FREQUENCY CAPABILITY Up to 50 kHz

PRODUCT CATEGORIES · THE RANGE

Six families.
Each engineered for a different application.

The product family is only the starting point. The final design depends on voltage, capacitance, current, duty cycle, frequency, cooling method, discharge behaviour, installation geometry, test requirement and operating environment.

Energy Storage / Discharge Capacitors
ESC · SERIES

Energy Storage / Discharge Capacitors

High-current pulse-discharge capacitors for applications where stored energy, discharge profile, peak current and low-inductance construction define the design.

Voltage Up to 160 kV DC
Energy Up to 50 kJ
Current >500 kA
Standard IS 13666

APPLICATIONS Pulse forming networks · Impulse and Marx generators · Laser systems · Radar systems · Cable fault location · Defence and research

View product →
High-Voltage DC / DC Filter Capacitors
HVDC · SERIES

High-Voltage DC / DC Filter Capacitors

High-voltage DC and DC filter capacitors for ripple smoothing, DC-link duty and high-voltage direct-current circuits where ripple current, ESR, voltage and thermal behaviour drive the design.

Voltage Up to 160 kV DC
Capacitance Up to 5000 µF
Duty Continuous DC
Standard IS 13666

APPLICATIONS HV DC supplies · Voltage multiplier circuits · Ripple filtering · Radar systems · SMPS · Converters and inverters · Traction supply filtering

View product →
Surge Protection Capacitors
SPC · SERIES

Surge Protection Capacitors

Surge capacitors and RC / CR suppressors for high-voltage motors, transformers, switchgear and vacuum-breaker circuits exposed to switching transients.

Voltage 3.3-36 kV
Impulse Up to 190 kVp
Rating 0.125-0.5 µF
Standard IS 11548

APPLICATIONS HT motor protection · Transformer protection · Arc-furnace transformers · Switchgear and generators · Vacuum-breaker circuits · Surge suppression

View product →
Water-Cooled / Air-Cooled Capacitors
WC / AC · SERIES

Water-Cooled / Air-Cooled Capacitors

Medium- and high-frequency capacitors for induction melting, hardening and heating systems where reactive output, frequency, RMS current, cooling and terminal geometry directly affect performance.

Output Up to 7200 kVAr
Voltage Up to 4.4 kV
Frequency Up to 50 kHz
Standard IEC 60110 / IS 9251

APPLICATIONS Induction melting · Induction hardening · Billet and bar heating · Forging and forming · IGBT-based induction heating · Heat treatment

View product →
PD-Free Voltage Dividers
PDV · SERIES

PD-Free Voltage Dividers

Capacitive voltage dividers for high-voltage measurement and test systems where partial-discharge behaviour, ratio accuracy and insulation performance are central to the design.

Voltage Per test system
PD level Per approved specification
Ratio Custom
Standard IEC 60270 / IEC 60358

APPLICATIONS HV test laboratories · AC high-voltage measurement · Calibration systems · Research institutions · PD-sensitive measurement applications

View product →
Import-Substitute Capacitors
ISC · CAPABILITY

Import-Substitute Capacitors

Capacitors developed against an existing imported unit, drawing, nameplate, sample or specification where the customer needs an India-built alternative after technical review.

Basis Sample / specification
Match Electrical + dimensional
Route Proven design / custom
Standard Application-dependent

APPLICATIONS Imported capacitor replacement · Obsolete units · Long-lead-time imports · Drawing-based development · OEM footprint matching · Special terminal layouts

Discuss requirement →

Our facility • In service

Made in Sangli.
Deployed worldwide.

From its manufacturing facility in Sangli, Marxelec supplies special-application capacitors to customers across 20+ countries. The work spans induction-heating duty, surge protection, high-voltage DC circuits, stored-energy systems, PD-sensitive measurement and import-substitute capacitor development.

WINDING
WINDING
Class 100 clean-room winding
Factory process
WINDING
WINDING
Class 100 clean-room winding
Factory process
IMPREGNATION
IMPREGNATION
Vacuum impregnation
Selected constructions
ASSEMBLY
ASSEMBLY
Application-specific configuration
Terminals · mounting · enclosure
TESTING
TESTING
Routine inspection before despatch
Applicable IEC / IS plan
Fabrication
Fabrication
Welding
SS, MS can Welding
Soldering
Soldering
Electrical connections by soldering
APPLICATION-VERIFIED ENGINEERING

Proven capacitor design where possible.
Custom-engineered where necessary.

Marxelec works from proven capacitor designs, modifies them where the application requires, and develops new designs where the electrical duty, geometry, cooling method, discharge behaviour or replacement requirement demands it.

For import-substitute work, the review goes beyond matching a drawing. Electrical rating, footprint, terminal layout, cooling condition, operating environment and applicable testing must be understood before the product route is confirmed.

Start technical review →
Standard / Modified / Custom Application Review
2
Working Days
INITIAL RESPONSE
IEC / IS APPLICABLE TEST PLAN
20+ EXPORT COUNTRIES
HOW WE WORK · SPEC TO DESPATCH

From requirement review
to tested despatch.

Every enquiry begins with a requirement. It may arrive as a complete specification, an old drawing, an imported part number, a failed sample, a nameplate photograph or only an application problem. Marxelec reviews what is available, clarifies what is missing and confirms the design route before manufacture.

01

Share specifications

Send the application, voltage, capacitance, frequency, current, duty cycle, cooling method, operating environment, drawing, part number or photographs.

02

Feasibility and engineering review

The sales and engineering teams review what is buildable, what needs clarification and which product route fits the requirement.

03

Initial response

Marxelec responds within two working days with the next step, clarification required or feasibility direction.

04

Drawing or specification review

Where required, a drawing, specification or key construction detail is shared for customer review before manufacture.

05

Quotation and lead time

Once the requirement is defined, Marxelec confirms the commercial offer, expected lead time and applicable inspection requirements.

06

Manufacture

The capacitor is manufactured through the approved design route: proven capacitor design, modified design or custom-engineered development.

07

IEC / IS testing

Each capacitor is tested against its applicable IEC or equivalent IS inspection and test plan. Relevant acceptance results are recorded before release.

08

Despatch

The capacitor is packed and despatched with the applicable test certificate and order documentation.

DOCUMENTATION

Product information
available on request.

Detailed product documentation is shared according to the capacitor family, application and enquiry stage. For special-application capacitors, the useful document is not always a generic catalogue; the right next step may be an application review followed by the relevant datasheet, drawing, inspection requirement or test documentation.

Start an enquiry

Tell engineering
what you are building.

Share the details you have: voltage, capacitance, frequency, current, duty cycle, cooling method, application context, drawing, existing part number, nameplate photograph or failed sample details. The first message does not need to be complete. It needs to start the technical review. Our team will respond within two working days.

DIRECT CONTACT

Marxelec Energy Pvt. Ltd.
Plot No. L-49, MIDC Kupwad
Sangli Miraj Kupwad
Sangli, Maharashtra 416436
India

response@marxelec.com